 EMI/EMC/RFI FILTERS - MEDICAL FILTERS
- TEMPEST FILTERS
- POWER LINE FILTERS
- LOW-LEAKAGE FILTERS
- Telephone Line Filters
- COMMUNICATION/DATA LINE FILTERS
- UL LISTED FILTERS
- MULTI-AGENCY LISTED FILTERS
- FACILITY FILTERS
- CUSTOM DESIGN FILTERS
- MULTICIRCUIT FILTERS
- TUBULAR AND SUBMINIATURE FILTERS (TECHNICAL DATA)
- MILITARY AND COMMERCIAL FILTERS
- HIGH CURRENT/VOLTAGE EMP FILTERS
- SECURE/SHIELDED INSTALLATIONS FILTERS
- POWER FACTOR CORRECTION COIL ASSEMBLIES
- FILTERED CIRCUIT BREAKER PANELS
 POWER LINE EMI/EMC/HEMP FILTERS EMI/RFI Power Filters for direct mounting to shielded room walls or facility power filters for entire shielded buildings. Full load testing IAW MIL-STD-220A and MIL-STD-188-125A. 100% Corona testing with our Biddle digital partial discharge system. RANGE: Voltage 12 Vdc - 5500 Vac Current .01 - 5000 Amps Frequency 50 - 400 Hz Attenuation 120 db from 9 KHz - 18 GHz
 Application High Voltage Power Line Filters (Primary Power) Voltage 5.5 kV line to line Current 370 Amps Frequency 50 Hz Insertion Loss 70 db @ 200 KHz 80 db @ 300 KHz 80 db @ 1 GHz Dimensions 5”H x 6”W x 30”D
 Application Military VME bus Custom computer filter Voltage 28 Vdc Current 4.5 Amps 2 x 15 Amps Insertion Loss 55 db @ .1 MHz 82 db @ 1.0 MHz 65 db @ 100 MHz Dimensions 2.24”H x 1.99”W x 3.24”D
 LOW LEAKAGE MEDICAL FILTERS RFI will design, develop and obtain agency (UL, CUL, VDE, etc.) approval for the medical filter applications requiring low leakage current to ground. This family of filters provides exceptional common-mode and differential mode insertion loss under actual operating conditions. Custom designs incorporate a variety of non-magnetic metal enclosures for maximum shielding effectiveness.
RANGE: Leakage Current 1 mA - 3 mA Voltage 115 - 660 Volts Current .01 - 300 Amps Frequency DC, 50, 60 & 400 Hz
Application: General purpose for medical & other electronic devices. Can be modified to meet customers spec. Voltage: 115-250 VAC Current: 2 X 5 Amps Frequency: 50-400 Hz Insertion Loss: 15 db @ 100 KHz 25 db @ 300 KHz 40 db @ 1 MHz 60 db @ 20 MHz Dimensions: .75 X 1.75 x 1.33
Application: General purpose for medical & other electronic devices. Can be modified to meet customers spec. Voltage: 115-250 VAC Current:  2 X 30 Amps Frequency: 50-400 Hz Insertion Loss: 15 db @ 100 KHz 25 db @ 300 KHz 40 db @ 1 MHz 55 db @ 20 MHz Dimensions: 1.5 X 3.31 X 3.87
 FILTERED TERMINALBLOCKS Standard and custom feed-thru filters pre-mounted on terminal blocks. This style makes it easy for factory and/or field connections. These filters incorporate feed-thru capacitors that use a film foil dielectric system and exhibit minimum capacitance drift from -50°C to +100°C. Available in C-LC-T-∏ configurations. RANGE: Voltage 24 - 1750 dc/ac Current 1 - 100 Amps Frequency DC - 400 Hz
 Power distribution filters for wireless communications Voltage 200 Vdc Current 55 Amps Insertion Loss 10 db @ 1 MHz 30 db @ 10 MHz 41 db @ 100 MHz 70 db @ 1 GHz Dimensions 2.2”H x 5.1”W x 1.1”D
 Power distribution filters for wireless communications Voltage 400 Vdc Current 30 Amps Insertion Loss 36 db @ 1 MHz 50 db @ 10 MHz 70 db @ 100 MHz 60 db @ 1 GHz Dimensions 2.2”H x 5.1”W x 1.1”D |